PROAM

Product Literature


ProAm is a simple, compact on-line analyser designed currently to accurately determine ammoniacal-nitrogen in real-time. Other parameters which include Nitrate, Chloride and Fluoride may also be configured. The instrument comprises a wall-mount analyser section with an integral sample pump; a controlling processor interfaced by a membrane keyboard and back lit LCD. Electrical connections for power supply and signals are externally made from a separate IP65 enclosure which is typically installed adjacent to the analyser section

  • ProAm
    Low cost, single stream analyser with automatic calibration/clean routines

PRINCIPLE OF OPERATION

The ProAm analyser uses an ammonia gas sensing ISE to report ammoniacal-nitrogen. Sample is delivered through large diameter tubing to a reaction vessel where a caustic / edta reagent is continuously added. The pH is elevated to liberate free-ammonia which is measured by the ion selective electrode (ISE). The sample is also temperature regulated / compensated and sparged with air to promote chemical mixing. The integral peristaltic sample pump can deliver sample directly from source or from a fast sample loop. A series of pinch valves are configured to control the passage of sample, calibration and cleaning fluids without introducing points of blockage thus improving reliability.




CONTROL AND MONITORING OPTIONS
Various options are available offering different levels of automation and communication. As standard, the instrument is supplied with an analogue output with its range determined by the selected calibration values. Four change-over contact relays (volt-free) are also available; two may be configured as limit alarms and two may be programmed to indicate various fault conditions. Alternatively, data may be transmitted to telemetry using Profibus or Modbus (other protocols are available on request). The instrument may be configured for continuous or intermittent analysis and controlled remotely using the BUS system.


TYPICAL SPECIFICATIONS

Measuring Range:

0-1 up to 500 PPM (without dilution)

Repeatability:

+/- 2% or better

Enclosure:

GRP to IP65 protection

Analyser Dimensions:

410 (h) x 370 (w) x 230 (d) mm

Weight:

16 Kg

Signals Box Dimensions:

275 (w) x 185 (h) x 180 (d) mm

Outputs:

Analogue 0/4-20mA standard

Alarms:

2 process limit & 2 utility alarms

Power supply:

100 – 240 VAC 50/60Hz


Features
Fast response from 5 minutes
Two point automatic calibration
Automatic chemical cleaning
Continuous or intermittent analysis
No filtration to 200mg/L suspended solids
Telemetry outputs