Downloads
Products
PROTOC® is a fast, reliable and flexible on-line analyser system designed to accurately determine TOC/TC (Total Organic Carbon) concentrations in real time. The TOC analyser comprises a wall mount analyser section typically supplied complete with a controller, providing local display and outputting signals.
LABTOC® consists of an organics analyser, based on proven PPM PROTOC® chemical technology, an auto sampler capable of feeding between one and eighty eight seperate samples to the analyser during a single run, and an IBM-compatible PC with exclusive, user friendly software, which both controls the analytical process and monitors the results.
The ProAm Ammonia Monitor is a simple, compact on-line analyser designed currently to accurately determine ammoniacal-nitrogen in real-time. Other parameters which include Nitrate, Chloride and Fluoride may also be configured. The instrument comprises a wall-mount analyser section with an integral sample pump; a controlling processor interfaced by a membrane keyboard and back lit LCD. Parameters include Ammonia, Nitrate, SAC, Nitrite, Ortho-Phosphate and Total Phosphate.
Terminator is a simple, compact and innovative solution designed to automate the isolation of site discharges. The system comprises a surface mounted controller connected to an inflatable bladder which is permanently installed within a discharge pipe. It is simple to install, simple to operate and is an effective control measure providing protection against release of pollution.
On-line continuous measurement of Nitrate & SAC (UV) for water and waste-water applications (single stream)
On-line semi-continuous measurement of Phosphate for water and waste-water applications.
On-line continuous analyser allowing integration of up to 3 measurement modules for water and waste-water
applications (multiple stream)
On-line semi-continuous measurement of Total Nitrogen for waste-water applications
On-line semi-continuous measurement of Total Phosphate for waste-water applications
Digital interfacing and display to multiple sensors including the determination of pH, Redox, Conductivity, DO, Turbidity, MLSS, Ammonium and Nitrate with optional air cleaning suitable for water and waste water applications.
In-line continuous direct ISE measurement of Ammoniacal- Nitrogen for activated sludge applications [single or multiple parameter with optional dynamic correction]
In-line continuous measurement of Nitrate using direct ISE technology for activated sludge applications [single or multiple parameter with optional dynamic correction]
In-line optical Dissolved Oxygen measurement for water, waste-water and sludge applications [single and multiple sensor and parameter connection]
In-line Turbidity and Suspended Solids measurement for water, waste-water and sludge applications [single and multiple sensor and parameter connection]
In-line continual measurement of Nitrate & SAC (UV) for municipal waste-water applications [single and multiple sensor and parameter connection]
In-line Dissolved Oxygen measurement for water and waste-water applications [multiple parameter and multiple sensor connection]
In-line pH measurement for water and waste-water applications [multiple parameter and multiple sensor connection]
In-line Conductivity measurement for water and waste-water applications [multiple parameter and multiple sensor connection]
In-line pH or ORP measurement for water and waste-water applications Also the same applied to IQ Sensor Net
In-line Conductivity measurement for water and waste-water applications
In-line Dissolved Oxygen measurement for water and waste-water applications
Pre-mounted instrumentation onto surface mount panels including plumbing suitable for pH, DO, Conductivity, Turbidity and Chlorine suitable for drinking water measurement.
Fixed refrigerated & portable battery powered water samplers for automatic discrete & composite sample collection.
On- line water quality monitor that accommodate external sensor technology to measure free chlorine using an amperometric cell, with the possibility to also integrate pH, ORP, temperature, conductivity, turbidity and flow measurements.
On-line water quality monitor that accommodates reagents for DPD analysis to report free chlorine and/ or total chlorine with the possibility to also integrate pH, ORP, temperature, conductivity, turbidity and flow measurements.
In-line monitor using ultrasonic detection of the sludge blanket and continual compressed air cleaning of the sensor, suitable for installation within waste-water and drinking water treatment applications
On-line alarm detector using non-contact Laser measuring surface reflectance alarming floating oil films
On-line alarm detector using non-contact Laser measuring surface reflectance alarming floating oil films
Nephlometric turbidity measurement for raw and treated potable water quality measurement.
Ultrasonic detection of the sludge blanket in Clarifiers, primary & secondary settlement tanks for water and
waste-water applications.
waste-water applications.
Battery powered IQ system for temporary installation and data collection including pH, turbidity, ammonia and nitrate.
Trailer systems allowing temporary installation and monitoring using a combination of probe and analytical technologies.
Conformity
Resources
OMA-3 EXPLAINED..
Operator Monitoring Assessment introduced by EA to assess industry and promote MCERTS instrumentation